
Portable X-Ray
Dongmun DIG-360 portable X-ray paired with the Astel DRA-1417 flat-panel detector — Korean-engineered mobile imaging at the bedside, in theatre, or in the field.
A complete portable digital radiography setup.
Spine Care Bangladesh supplies a matched two-piece portable radiography system: the Dongmun DIG-360 high-frequency portable X-ray unit and the Astel DRA-1417SG / DRA-1417SC 14″ × 17″ flat-panel detector. Together they replace fixed radiography suites for many bedside, intra-operative and field imaging needs.
Every unit ships with clinical handover, biomedical training and an on-site service plan — the system is in clinical use the same day it arrives.
70 kHz inverter delivers a cleaner waveform and shorter exposure time than conventional generators — sharper images at lower patient dose.
DIG-360 weighs under 10 kg in its carry-handle housing. One technician can move it between OT, ICU and ward — no trolley required.
The Astel flat-panel detector replaces film and CR cassettes. Image preview on the console in seconds, native DICOM straight into hospital PACS.
The X-ray generator and the detector
One mobile generator + one digital detector — a complete digital radiography setup that fits inside a single carry case.

Dongmun DIG-360
Compact high-frequency portable X-ray generator in a single carry-handle housing — designed for OT, ICU, emergency and field use. Lightweight 9.8 kg chassis with 1.6 kW output and 4-program anatomy memory.
- Output
- 1.6 kW
- Tube current
- 20 mA
- kVp range
- 40 – 100 kV (1 kV steps)
- mAs range
- 0.3 – 50 mAs (22 steps)
- Frequency
- 70 kHz inverter
- Focal spot
- 1.2 mm
- Anatomy programs
- 4 pre-set selections
- Power input
- 110 / 220 V, 50 / 60 Hz
- Dimensions
- 350 × 157 × 170 mm
- Weight
- 9.8 kg — single-person portable

Astel DRA-1417SG / DRA-1417SC
Cassette-size digital radiography detector that pairs with the DIG-360. Replaces film and CR cassettes — image preview on the console in seconds, native DICOM, ready for PACS.
- Pixel matrix
- 2500 × 3052
- Effective area
- 347.8 × 425.04 mm (14″ × 17″)
- Effective array
- 2484 × 3036
- Spatial resolution
- 3.4 lp/mm
- ADC resolution
- 16-bit · 65,536 grayscales
- X-ray voltage range
- 40 – 150 kVp
- Trigger
- Line trigger (manual) / AED (auto)
- Wired power
- DC +15 V
- Wireless battery
- 11.8 V, ~4 hr per pack
- Dimensions
- 384 × 460 × 15 mm
- OS support
- Windows 7 / 8 / 10 (32 / 64-bit)
Built for everyday clinical use
High-frequency generator
70 kHz inverter delivers a cleaner waveform and shorter exposure time than conventional generators — sharper images at lower patient dose.
Truly portable, 9.8 kg
DIG-360 weighs under 10 kg in its carry-handle housing. One technician can move it between OT, ICU and ward — no trolley required.
Direct digital workflow
The Astel flat-panel detector replaces film and CR cassettes. Image preview on the console in seconds, native DICOM straight into hospital PACS.
16-bit image quality
65,536 grayscales and 3.4 lp/mm spatial resolution — fine bony detail for spinal hardware verification and small-fragment fracture imaging.
Pre-set anatomy programs
Four anatomy programs on the DIG-360 console mean exposure is set in a single button-press for routine views — less variability between operators.
Korean manufacture
Both Dongmun and Astel manufacture in Korea under their respective medical-device QMS — full traceability and proper Bangladesh after-sales support through us.
Where portable X-ray is used
See the DIG-360 + Astel FPD in your department.
Our team can arrange an in-hospital demonstration of the Dongmun portable X-ray and Astel flat-panel detector for your radiology, OT and ICU teams.